Dirt DevilŪ Central Vacuum Performance Specifications -

PERFORMANCE

CV1800

Best suited for homes up to 2,500 square feet.

CV2200

Dynamic
The perfect choice for homes up to 5,000 square feet.

CV2600

Dynamic
Optimum cleaning power for homes between 5,000 to 8,000 square feet.

CV3200

Dynamic
Twin Motor vacuum power for homes up to 12,000 square feet.

MaxAir®

Twin Motor vacuum power for homes up to 22,000 square feet.

 

Max Air Watts*

422

520

575

848

903

Sealed Vacuum (H20 lift)

106"

125"

141"

106"

208"

CFM Max

115

121

124

221

122

Motor

EMI 5.7" 2-stage
120V / 60 Hz.

Ametek 5.7" 2-stage
120V / 60 Hz.

Ametek 5.7" 2-stage
120V / 60 Hz.

(2) Ametek 5.7" 2-stage
240V / 50/ 60 Hz.

(2) Ametek 5.7" 2-stage
240V / 50/60 Hz.

Level of Quietness dB***

73.7 dBA

64.2 dBA

62.8 dBA

67.8 dBA

n/a

FEATURES


Filtration

Filtered cyclonic, 7" replaceable pleated cartridge

Filtered cyclonic, 7" replaceable pleated cartridge

Filtered cyclonic, 7" replaceable pleated cartridge

Filtered cyclonic, 10 " replaceable pleated cartridge

True Cyclonic, requires no bags or filters

Dirt Pan Construction

Durable ABS construction with comfort-grip bottom

Durable ABS construction with comfort-grip bottom

Durable ABS construction with comfort-grip bottom

Durable ABS construction with comfort-grip bottom

Durable ABS construction with comfort-grip bottom

Dirt Pan Capacity

4 gallons

6 gallons

6 gallons

6 gallons

6 gallons

Low Voltage Controls

24 V PC Board

24 V PC Board

24 V PC Board

24 V PC Board

24 V PC Board (2 single pole relays)

Overload Heat Protection

Pushbutton resettable circuit protector

Pushbutton resettable circuit protector

Pushbutton resettable circuit protector

Pushbutton resettable circuit protector

2 pushbutton resettable circuit protector

Warranty

Lifetime Limited
3-years on accessories

Lifetime Limited
3-years on accessories

Lifetime Limited
3-years on accessories

Lifetime Limited
3-years on accessories

Lifetime Limited
3-years on accessories

Construction

20 gauge steel Powder-coated finish

20 gauge steel Powder-coated finish

20 gauge steel Powder-coated finish

20 gauge steel Powder-coated finish

20 gauge steel Powder coated finish

Dimensions/Weight

13" dia. x 31 3/8" high
23 pounds

13" dia. x 39 5/8" high
32 pounds

13" dia. x 39 5/8" high
32 pounds

13" dia. x 44 " high
34.5 pounds

12-5/8" x 44" tall 51 lbs.

INSTALLATION


Electrical Requirements

• 120V/60Hz, 1 ph,
  15 amp circuit
• Separate circuit
  recommended
• 6' cord for NEMA
  type 5-15R
  receptacle with
  grounding wire

• 120V/60Hz, 1 ph,
  15 amp circuit
• Separate circuit
  recommended
• 6' cord for NEMA
  type 5-15R
  receptacle with
  grounding wire

• 120V/60Hz, 1 ph,
  15 amp circuit
• Separate circuit
  recommended
• 6' cord for NEMA
  type 5-15R
  receptacle with
  grounding wire

• 240V/60Hz, 1 ph,
  15 amp circuit
• Separate circuit
  recommended
• 6' cord for NEMA
  type 6-15
  receptacle with
  grounding wire

• 240V 50/60Hz,
  15 or 20 amp circuit
• Separate circuit
  required
• 6' cord for NEMA
  type 6-15
  receptacle with
  grounding wire

Mounting Requirements

Basement, garage, utility room. Mounting bracket mounted on wall stud or masonry wall.

Basement, garage, utility room. Mounting bracket mounted on wall stud or masonry wall.

Basement, garage, utility room. Mounting bracket mounted on wall stud or masonry wall.

Basement, garage, utility room. Mounting bracket mounted on wall stud or masonry wall.

Basement, garage, utility room. Prefer outside wall. Mounting bracket mounted on wall stud or masonry wall. Single exhaust, muffler included. Metal tubing required for exhaust line. Must be exhausted outside.




back to top


* ASTM recognizes air watts as air power and is defined as "above the floor cleaning potential."

** Maximum amps refer to the potential amount of current if the power unit is running in a stand-alone situation. (no tubing or accessories attached). Average amps refer to the actual amount of current used when the power unit is in typical operation (installed, with accessories attached).

*** ASTM draft F11.50.07 test method was used to determine dBA ratings. Sound levels were measured at 6' from the power unit. All power units were exhausted outdoors.